I/O Units with TRDP

RRT2-xxx are remote I/O units designed and optimized to control rolling stock. Units communicate with other parts of TCMS through TRDP protocol. The units meet the requirements of EN 50155 (Electronic equipment used on rolling stock) class TX.

 

Protocol

TRDP TCNOpen 1.3.3.0

Ethernet

Ethernet connector M12

Power supply

24 V  (-30 % až +25 %)

Protection rate

IP30

Operating temperature

-40 °C to 70 °C

Mounting

35 mm DIN rail

Dimensions (w × h × d)

199 mm × 110 mm × 69 mm

Standards

EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2

 

Types available:

input / outputDIDOAIAO
RRT2-IO/xx168
RRT2-AIO/xx1684
RRT2-I/xx32

 